AAC Blocks Technical Specifications

PRODUCT TECHNICAL DATA

AAC Blocks Technical Specifications

Review editable technical parameters for DARAAC AAC Blocks, including standard masonry blocks, enhanced fireproof blocks, high-strength seismic blocks and crack-resistant wall blocks. Final product selection, dimensions and compliance documents are confirmed against the project requirement and destination-market standard.

Sound Insulation & Fireproof AAC Blocks

Suitable for lightweight masonry walls requiring thermal insulation, sound reduction and reliable fire performance.

Sound Insulation & Fireproof AAC Blocks - B06 A3.5
Specification Item Technical Parameter
Grade B06 A3.5
Available Dimensions (L x W x H) 600 x 100 / 120 / 150 / 200 / 240 / 250 x 250 mm
Average Compressive Strength ≥ 3.7 MPa
Dry Density ≤ 625 kg/m³
Thermal Conductivity 0.15 W/(m.K)
Freeze-Thaw Mass Loss ≤ 5.0%
Drying Shrinkage ≤ 0.50 mm/m

Enhanced Fireproof AAC Blocks

A lower-density option with a broad range of thicknesses for fire-rated and thermally efficient wall applications.

Enhanced Fireproof AAC Blocks - B05 A3.5
Specification Item Technical Parameter
Grade B05 A3.5
Available Dimensions (L x W x H) 600 x 30 / 40 / 100 / 120 / 150 / 200 / 240 / 300 x 250 mm
Average Compressive Strength ≥ 3.6 MPa
Dry Density ≤ 525 kg/m³
Thermal Conductivity 0.13 W/(m.K)
Freeze-Thaw Mass Loss ≤ 5.0%
Drying Shrinkage ≤ 0.50 mm/m

High-Strength Seismic AAC Blocks

Designed for projects that need higher compressive strength while retaining the practical advantages of lightweight AAC masonry.

High-Strength Seismic AAC Blocks - B06 A5.0
Specification Item Technical Parameter
Grade B06 A5.0
Available Dimensions (L x W x H) 600 x 100 / 120 / 150 / 200 / 240 / 250 x 250 mm
Average Compressive Strength ≥ 5.1 MPa
Dry Density ≤ 625 kg/m³
Thermal Conductivity 0.15 W/(m.K)
Freeze-Thaw Mass Loss ≤ 5.0%
Drying Shrinkage ≤ 0.50 mm/m

Super High-Strength Seismic Fireproof AAC Blocks

A high-strength AAC block option in 200 mm and 240 mm thicknesses for demanding wall-system requirements.

Super High-Strength Seismic Fireproof AAC Blocks - B06 A5.0
Specification Item Technical Parameter
Grade B06 A5.0
Available Dimensions (L x W x H) 600 x 200 / 240 x 250 mm
Average Compressive Strength ≥ 5.1 MPa
Dry Density ≤ 625 kg/m³
Thermal Conductivity 0.15 W/(m.K)
Freeze-Thaw Mass Loss ≤ 5.0%
Drying Shrinkage ≤ 0.50 mm/m

Enhanced Crack-Resistant AAC Blocks

Lightweight AAC blocks for wall construction where crack resistance and improved thermal performance are required.

Enhanced Crack-Resistant AAC Blocks - B05 A3.5
Specification Item Technical Parameter
Grade B05 A3.5
Available Dimensions (L x W x H) 600 x 150 / 200 / 250 x 250 mm
Average Compressive Strength ≥ 3.5 MPa
Dry Density ≤ 525 kg/m³
Thermal Conductivity 0.11 W/(m.K)
Freeze-Thaw Mass Loss ≤ 5.0%
Drying Shrinkage ≤ 0.50 mm/m

Values shown above are product reference data. Please contact DARAAC with the required application, dimensions, quantity and destination country for a project-specific recommendation.

Need a project-specific AAC block specification?

Send your wall application, required size and destination market to our technical sales team.

Request AAC Block Information